
Hikvision and ZKTeco · Independent service · 24/7
Hikvision and ZKTeco Access Control Installation and Repair in Dubai and Abu Dhabi
Hikvision and ZKTeco access control is everywhere in the UAE, from villa video intercoms to face recognition readers at office doors and turnstiles in building lobbies. We install and service these systems in Dubai and Abu Dhabi. We are an independent service company and are not affiliated with or authorised by Hikvision and ZKTeco. We fix offline devices, locks that will not release, readers that reject users and intercoms with no picture, and we link them to gates and barriers. Call or WhatsApp 050 495 3512.
- Open 24/7, including Fridays and holidays
- Dubai and Abu Dhabi
- No charge for the site visit
- 24/7 call-outs
- Same-day visits
- Free site visit
- Written quote first
- English and Arabic
- All major brands
We are an independent service company and are not affiliated with or authorised by Hikvision and ZKTeco. Brand names are used only to describe the equipment we service.
Hikvision and ZKTeco access control we see in Dubai and Abu Dhabi
Both brands make a wide range of access control hardware, and we usually meet them as part of a door, gate or barrier system rather than on their own. A typical setup has a reader or intercom at the entry point, a controller that decides who is allowed in, a lock or gate motor that the controller releases, and an exit button or sensor on the inside.
We install new systems and service existing ones, including systems put in by other contractors.
- Villa video intercoms: outdoor door station at the gate, indoor monitor and phone app, often releasing a gate motor or electric lock
- Apartment and building intercoms with a lobby panel and flat monitors
- Face recognition and fingerprint terminals at office doors, clinics and staff entrances, sometimes also used for attendance
- Card and PIN readers wired to access controllers on doors, lifts and car park entries
- Turnstile, speed gate and barrier controllers in tower lobbies, gyms, warehouses and labour accommodation in Al Quoz, Jebel Ali and Mussafah
Common faults in UAE heat, sand and humidity
Outdoor readers and door stations take the full force of a Dubai summer. Screens and camera lenses fade or fog, rubber seals crack, and units in direct sun run very hot. Face recognition can struggle when the camera faces strong low sun or a bright glass lobby behind the person, and fingerprint sensors lose accuracy with dust on the glass or very dry skin.
Most other faults come from the infrastructure around the device. A failed power supply or backup battery, a loose network cable, a PoE switch that has dropped a port, or an IP address clash after a router change will all make a device go offline. Magnetic locks stop holding when the armature plate works loose or the supply voltage sags, and electric strikes jam when the door drops on its hinges.
Power cuts can also reset the clock on some devices. If time schedules or attendance records look wrong after an outage, the date and time settings are the first thing we check. Near the coast, humid air corrodes connectors and terminals in outdoor boxes.

Access control fault table: symptom, cause and fix
| Symptom | Common cause | What we do |
|---|---|---|
| Device shows offline in the app or software | Network cable, PoE port, IP address clash or router change | Test the cabling and switch, fix addressing, reconnect the device |
| Reader accepts the user but the door stays locked | Relay, lock wiring, lock power supply or a failed lock | Trace the release circuit, repair wiring, replace lock or supply |
| Magnetic lock does not hold | Loose or misaligned armature plate, low voltage, dirty contact faces | Realign and refix plate, clean faces, check power supply |
| Face recognition fails at certain times of day | Direct sun or strong backlight on the camera | Adjust settings, add a hood or reposition the terminal |
| Fingerprint reader rejects staff | Dirty or scratched sensor, poor enrolment, dry skin | Clean or replace sensor, re-enrol with more fingers or add a card |
| Card not reading | Wrong card type for the reader, damaged card or reader | Check card technology, replace card or reader |
| Intercom has no picture or no sound | Cable fault, failed camera module, water entry | Test cable and power, repair or replace the door station |
| Gate or turnstile does not open on a valid read | Controller output not wired or set to the motor input | Rewire and set the output, test with the gate or turnstile controller |
Spare parts and hardware we carry or source
We carry common access control hardware and source Hikvision and ZKTeco devices where available in the UAE. When a model is discontinued we fit a current equivalent, or a compatible device from another brand, and move the users across where the systems allow it.
- Power supplies with battery backup, and replacement backup batteries
- Magnetic locks, armature plates, brackets and electric strikes
- Exit buttons, break glass units and door contacts
- Card readers, keypads, access cards and key fobs
- Indoor monitors and outdoor door stations
- Access controllers and relay modules
- Network switches, PoE injectors and outdoor-rated cabling

Adding users, faces and cards
Users can usually be enrolled at the device itself through its admin menu, or centrally through the manufacturer's management software or mobile app. Faces need a clear, well lit enrolment photo; fingerprints work best with two or more fingers enrolled; cards must be the same technology as the reader. Steps differ by model and software version.
We set up admin access, add and remove users, build time schedules for staff and cleaners, and hand over the admin details to you. On villa intercoms we add family members to the phone app so they can see visitors and open the gate remotely. For buildings we can link the reader to a gate motor, boom barrier or turnstile so one credential opens every entry point.
- Co
- Ch
- En
- Se
- Te
Safety and fire alarm links
Doors on escape routes must let people out at all times. Magnetic locks are usually wired to release when the fire alarm activates, and an emergency break glass unit should cut power to the lock. Where the building's fire strategy requires it, we connect and test these links and check that exit buttons and break glass units work on every controlled door.

Maintenance schedule for access control systems
- Villas: yearly check of the intercom, lock, power supply and gate release
- Offices, clinics and buildings: every 3 to 6 months
- Each visit: clean readers and camera lenses, test locks, exit buttons and break glass units, check power supply and battery
- Each visit: check network status, clock settings and storage, and remove users who have left
- Before summer: check seals and shading on outdoor units
Repair or replace
Most access control faults are in cabling, power, locks or settings and can be fixed without new devices. A reader or door station with water damage, a failed screen or camera, or firmware that is no longer supported is usually better replaced.
If a model is no longer available, we fit a current one or a compatible reader from another brand. Many controllers accept common reader interfaces such as Wiegand, which makes partial upgrades possible. Repair and replacement options are set out in a written quote.
What happens on a visit and where we work
In Dubai we cover Business Bay, Downtown, Dubai Marina, JLT, Al Barsha, Jumeirah, Arabian Ranches, Dubai Hills, Al Quoz and Jebel Ali. In Abu Dhabi we cover Al Reem Island, Khalifa City, Al Raha, Saadiyat and Mussafah. Other emirates on request. Calls are answered 24/7, and the site visit and quote are free.
- Ca
- A
- Yo
- We
Related services and products
Related searches
- video intercom systems installation dubai
- video intercom installation dubai
- turnstile installation dubai
- turnstile dubai
- speed gates
- automatic speed gate dubai
- gate motor repair dubai
- gate motor repair
- beninca repair dubai
- bft repair dubai
- came repair dubai
- ditec repair dubai
- dormakaba repair dubai
- faac repair dubai
Recent jobs by our team

Rolling shutter motor replacement, Al Karama, Dubai 
Sliding gate motor installation, Al Yasmeen, Ajman 
Swing gate motor installation, an Abu Dhabi villa 
Sliding gate motor installation, Ghantoot 
Black garage door installation, Palm Jumeirah, Dubai 
Garage door installation, Jebel Ali, Dubai
Photos from real jobs by our team across Dubai, Abu Dhabi and the northern emirates.
Hikvision and ZKTeco service across Dubai and Abu Dhabi
Hikvision and ZKTeco: frequently asked questions
Do you install and repair Hikvision and ZKTeco access control in Dubai?
Yes. We install and service Hikvision and ZKTeco video intercoms, face, fingerprint and card readers, access controllers and turnstile controllers across Dubai and Abu Dhabi, including systems put in by other contractors.
Are you connected to Hikvision or ZKTeco?
No. We are an independent service company and are not affiliated with or authorised by Hikvision and ZKTeco. We install and service their equipment along with other common access control brands.
Why is my access control device showing offline?
Usually a network problem: a loose cable, a PoE switch port that has dropped, an IP address clash or a router change. A failed power supply also causes it. We test the cabling, power and settings and reconnect the device.
The reader beeps green but the door does not open. What is wrong?
The reader is accepting the user, so the fault is usually in the release circuit: the relay, lock wiring, lock power supply or the lock itself. We trace the circuit and repair or replace the failed part.
Why does face recognition fail in the afternoon?
Strong direct sun or a bright background behind the person makes faces hard for the camera to read. Adjusting settings, adding a hood or moving the terminal usually solves it. We check it at the time of day it fails.
Can you add new staff or remove people who have left?
Yes. We enrol faces, fingerprints, cards and PINs at the device or through the management software, set time schedules and remove old users. If the admin password is lost, we reset access with the owner present.
Can my villa intercom open the gate from my phone?
On many intercoms yes. The door station is wired to release the gate motor or lock, and the phone app lets family members see visitors and open the gate. We set up the wiring and add each family member.
Can a Hikvision or ZKTeco reader open a turnstile or barrier?
Yes. The access controller output is wired to the turnstile, speed gate or barrier controller so a valid face, card or fingerprint opens it. We set and test the wiring and direction on site.
Do magnetic locks release in a fire alarm?
They should on escape routes. Locks are usually wired to release when the fire alarm activates and when a break glass unit is pressed. Where the building's fire strategy requires it, we connect and test these links.
What affects the cost of an access control job?
The number of doors, the device type, cabling distances and routes, lock type, network work, and whether users must be moved from an old system. Every job gets a free site visit and a written quote before work starts.
Do you cover Abu Dhabi?
Yes. We cover Abu Dhabi including Al Reem Island, Khalifa City, Al Raha, Saadiyat and Mussafah, as well as all of Dubai. Call or WhatsApp 050 495 3512, any time.
Other brands we service
Hikvision and ZKTeco not working?
Call or WhatsApp with a photo of the unit and its label. Free site visit and a written quote before any work.